The seismic assessment of an existing masonry building presents the structural engineer with a series of decisions that rarely have a single, straightforward answer: how to model the structure, which mechanical parameters to adopt, how to interpret capacity curves, and when a local mechanism is truly critical.
This 5-part video course series in Italian follows a real-world case study—the seismic improvement of an existing masonry school building—from model creation to comparing the pre- and post-intervention scenarios.
This case study is the one presented at the seminar on June 24, 2026, “Il metodo a telaio equivalente per la valutazione sismica di edifici in muratura: il Solutore SAM II dalla teoria alla pratica professionale”, organized in collaboration with 2PS Formazione Tecnica.
The objective is not to show a procedure to be mechanically replicated, but rather to make explicit the criteria behind modeling decisions and the interpretation of results. Model validation and the verification of results remain, as always, the responsibility of the structural engineer.
Tools used: PRO_SAP for modeling and structural analysis, PRO_SAM for pushover analysis using the equivalent frame method (SAM II solver), and PRO_CineM for local mechanism verification.
01 — Introduzione e analisi senza sisma
The first episode frames the case study and sets up the model.
It covers the presentation of the building, its geometry, the structural modeling choices, the definition of materials and masonry mechanical parameters, load application, and gravity load analysis.
While engineers often tend to rush through this phase to get to the seismic analysis, the choices made here dictate the reliability of everything that follows: capacity curves, failure mechanisms, and risk indicators are all built upon these baseline assumptions.
02 — PRO_SAM: pushover globale con il metodo a Telaio Equivalente (SAM II)
The second episode covers the global pushover analysis using the equivalent frame method via the SAM II solver.
It illustrates the setup of the non-linear analysis, the definition of parameters governing masonry element behavior, the execution of analyses across different directions and force distributions required by code, and the preliminary reading of capacity curves.
The SAM II solver is developed in collaboration with the University of Pavia and the EUCENTRE Foundation, who are its scientific authors.
03 — Ok, ho le curve… e adesso?
The third episode is dedicated to what happens after the analysis: reading and interpreting the results.
Having capacity curves does not mean having an answer. One must understand how capacity compares to seismic demand, which mechanisms govern failure, and whether the obtained values are reasonable.
This is the stage where analysis becomes assessment, and where engineering judgment carries more weight than the tool itself.
04 – PRO_CineM: verifica dei meccanismi locali fuori piano
The fourth episode covers local out-of-plane collapse mechanisms using PRO_CineM.
Available starting August 12.